The backdoors are as follows:
- Telnet port – May allow remote attackers the ability to view the operation of the module’s firmware, cause a denial of service, modify the memory of the module, and execute arbitrary code.
- Windriver Debug port – Used for development; may allow remote attackers to view the operation of the module’s firmware, cause a denial of service, modify the memory of the module, and execute arbitrary code.
- FTP service – May allow an attacker to modify the module website, download and run custom firmware, and modify the http passwords.
- Modicon PLCs can be compromise via the NOE Ethernet modules through ftp, telnet, modbus, WDB, snmp, web etc.
- An attacker could load their own trojanized firmware.
- There are non-documented hidden accounts that can be used to compromise a PLC.
Quantum
- 140NOE77101 Firmware Version 4.9 and all previous versions.
- 140NOE77111 Firmware Version 5.0 and all previous versions.
- 140NOE77100 Firmware Version V3.4 and all previous versions.
- 140NOE77110 Firmware Version V3.3 and all previous versions.
- 140CPU65150 Firmware Version V3.5 and all previous versions.
- 140CPU65160 Firmware Version V3.5 and all previous versions.
- 140CPU65260 Firmware Version V3.5 and all previous versions.
- TSXETY4103 Firmware Version V5.0 and all previous versions.
- TSXETY5103 Firmware Version V5.0 and all previous versions.
- TSXP571634M Firmware Version V4.9 and all previous versions.
- TSXP572634M Firmware Version V4.9 and all previous versions.
- TSXP573634M Firmware Version V4.9 and all previous versions.
- TSXP574634M Firmware Version V3.5 and all previous versions.
- TSXP575634M Firmware Version V3.5 and all previous versions.
- TSXP576634M Firmware Version V3.5 and all previous versions.
- BMXNOE0100 Firmware Version V2.3 and all previous versions.
- BMXNOE0110 Firmware Version V4.65 and all previous versions.
- BMXP342020 Firmware Version V2.2 and all previous versions.
- BMXP342030 Firmware Version V2.2 and all previous versions.
- STBNIC2212 Firmware Version V2.10 and all previous versions.
- STBNIP2311 Firmware Version V3.01 and all previous versions.
- STBNIP2212 Firmware Version V2.73 and all previous versions.
Schneider Electric has created a fix for the Telnet and Windriver debug port vulnerabilities for the BMXNOE0100 and 140NOE77101 modules by removing them from the firmware. The fixes will be published on the Schneider website.